Welcome to Fluke Fiber 06: LinkWare Projects & Reporting

Course Duration: 35–45 minutes

A certification is only as good as its report. This course covers Fluke's data workflow: ProjX projects on the Versiv, LinkWare Live in the cloud, and LinkWare PC reports, so every test is labeled correctly, uploaded, reviewed, and delivered as a complete, defensible package.

What You'll Learn:

  • Explain how ProjX, LinkWare Live, and LinkWare PC fit together
  • Build ProjX projects with test setups and cable ID sets
  • Use LinkWare Live projects, sync, uploads, and tester tracking
  • Import, merge, and organize results in LinkWare PC
  • Produce complete customer reports and avoid documentation errors

Course Structure

  1. The Versiv Data Workflow
  2. ProjX Projects on the Tester
  3. LinkWare Live in the Cloud
  4. LinkWare PC: Import & Organize
  5. Building Customer Reports
  6. Documentation Quality & Common Errors
  7. Final Assessment — 10 questions, 80% (8 of 10) to pass

Each section ends with a knowledge check. You get two attempts, and a first miss gives you a hint, not the answer. Finish the check to unlock the next section. You'll enter your name and email just before you submit the final assessment. Your results are emailed automatically to the training administrator, with a copy to you, whether you pass or not.

Section 1: The Versiv Data Workflow

Certification isn't finished when the tester says PASS. It's finished when the customer has an accurate, complete report. Fluke's workflow has three pieces:

PieceWhere it runsWhat it does
ProjX™On the Versiv testerOrganizes a job's test setups (limits, fiber types) and cable IDs, and tracks completion from 0 to 100%
LinkWare™ LiveCloud (browser or phone)Creates projects and setups, syncs them to testers, receives results over Wi-Fi from the jobsite, shows dashboards, and tracks testers
LinkWare™ PCWindows PCImports or downloads results, organizes and merges projects, and produces the reports the customer receives
Plan (LinkWare Live or ProjX) → Test (Versiv: CertiFiber Pro, OptiFiber Pro, FI-7000) → Upload (Wi-Fi to LinkWare Live, or USB to LinkWare PC) → Review → Report (LinkWare PC)

The same workflow handles copper (DSX), OLTS (CertiFiber Pro), OTDR (OptiFiber Pro), and inspection images (FI-7000).

Knowledge Check 1
Which piece of the Fluke workflow runs on the tester and organizes setups and cable IDs?
Attempts: 0/2

Section 2: ProjX Projects on the Tester

  1. PROJECT › CHANGE PROJECT › NEW PROJECT, and name it after the job (customer, site, phase).
  2. Add a test setup for each kind of link: for example, OM4 Tier 1, TIA-568.3-E, 1 jumper, 2 connections, and OS2 backbone.
  3. Add cable ID sets: sequential (FDP1-001 to FDP1-048) or a custom list that matches the drawings and labels.
  4. Test. Each result is saved under the next cable ID, and ProjX shows how complete the project is.

Why it matters

  • The correct limit and settings follow each cable ID automatically, so there are fewer wrong-limit tests.
  • Cable IDs match the physical labels, so the report matches the building.
  • The completion status shows what's left, so nothing gets missed.
Tip: Build the project before you get to site: either in the office on the tester, or in LinkWare Live and sync it down.
Knowledge Check 2
Why use cable ID sets that match the labeling plan?
Attempts: 0/2

Section 3: LinkWare Live in the Cloud

LinkWare Live is Fluke's cloud service for managing certification jobs. It's sold as subscription plans:

PlanIncludes (Fluke datasheet)
EssentialsResult uploads, project dashboards, results analysis and troubleshooting, summary certification reports, and tester location and status
ProfessionalEverything in Essentials, plus creating and distributing test setups, real-time setup corrections, and notifications when tests use the wrong limits or cable IDs

Typical flow

  1. On the DASHBOARD, create a New Project (split big jobs, for example one per floor or per backbone).
  2. Add a New Test Setup (media, cable type, tests) and a New Cable ID Set (sequential or custom).
  3. Set the project Status to Active (leave unfinished ones as Draft).
  4. Sync the tester to pull down the setups and cable IDs, then test and upload the results over Wi-Fi from the jobsite.

Managing testers

  • Shows each tester's last location and who's using it.
  • Warns 60 days before calibration is due.
  • Shows firmware versions, and can update testers remotely.
  • Sub-managers, techs, and viewers can be invited by role, which is useful for subcontractors.
Knowledge Check 3
Which LinkWare Live plan adds notifications when tests are run with the wrong limits or cable IDs?
Attempts: 0/2

Section 4: LinkWare PC: Import & Organize

LinkWare PC is free Windows software, and you can give copies to customers.

Getting results in

  • From the tester: connect it and click Import. Choose all results or only selected ones.
  • From LinkWare Live: click the transfer icon, sign in with your Fluke Networks ID, choose the project, and import the records to a destination file.
  • Merging: add new results to an existing project file, then sort and search by any field.

Organizing

  • Keep one project file per job, with folders for each building, floor, or phase.
  • Check for duplicate cable IDs, and for results taken with the wrong limit, before you report.
  • LinkWare also checks for and installs tester firmware updates, including on remote units.
Knowledge Check 4
How do you bring results from LinkWare Live into LinkWare PC?
Attempts: 0/2

Section 5: Building Customer Reports

Report type (LinkWare PC)ShowsUse for
SummaryOne line per link: ID, date and time, PASS/FAIL, headroomThe customer's overview and close-out list
TextNumeric worst-case values and marginsDetailed review
GraphicalFull results with graphs (and OTDR traces)The full certification record

What a fiber report should include

  • Cable ID and location matching the labels and drawings
  • Test limit, reference method, fiber type, and connection/splice counts
  • Loss, length, and margin for each fiber and wavelength (Tier 1). Trace and event table if Tier 2 was done.
  • End-face inspection images (FI-7000) when they were captured
  • Date and time, technician, and the tester model, serial number, and calibration date
  • Your company logo and the project name

Export the report as PDF, and keep the native project file. It holds the raw data, which a PDF can't be re-analyzed from.

Five 9s close-out: Summary report plus full graphical report, both as PDFs, plus the LinkWare project file, delivered to the customer and archived with the job.
Knowledge Check 5
Which LinkWare PC report shows one line per link with ID, date, PASS/FAIL, and headroom?
Attempts: 0/2

Section 6: Documentation Quality & Common Errors

ErrorConsequencePrevention
Wrong limit or reference method on some linksInvalid results: retest, or a rejected warrantyUse test setups from ProjX or LinkWare Live, and turn on wrong-limit notifications (Professional)
Cable IDs don't match the labelsThe report can't be matched to the buildingBuild ID sets from the labeling plan before testing
Missing linksIncomplete certificationCheck ProjX completion and the Summary report against the drawings
Only the passing retest keptNo proof of what was fixedKeep both the original FAIL and the passing retest
Calibration expiredThe report can be challengedWatch LinkWare Live's 60-day calibration warning
Only the PDF keptNo raw data for later disputesArchive the LinkWare project file too
Knowledge Check 6
Why archive the LinkWare project file and not just the PDF?
Attempts: 0/2

Final Assessment

Answer all 10 questions. You need 80% (8 of 10) to pass. These questions are different from the section knowledge checks. Enter your name and email below the questions, then submit.

1. What does ProjX show as testing proceeds?
2. How do Versiv testers send results to LinkWare Live from the jobsite?
3. How far ahead does LinkWare Live warn that a tester's calibration is due?
4. In LinkWare Live, what status must a project have before testers can use it?
5. What does LinkWare PC cost?
6. What does merging do in LinkWare PC?
7. Which belongs in a fiber certification report?
8. A link failed, was cleaned, and passed on retest. What should the project keep?
9. Can LinkWare PC update tester firmware?
10. What is the Five 9s close-out package for a fiber job?