➰ WireXpert Loopback Setup & Testing

Single-Ended Testing & Reference Integrity — Five 9s Communications

1
2
3
4
5
6
0 of 6 Sections Complete

Welcome to WireXpert Loopback Setup & Testing Training

Course Duration: 35–50 minutes

Sometimes you're on your own, or the REMOTE unit is somewhere else. This module covers what the WireXpert MP can do with only the LOCAL unit (fiber single-ended loopback and the copper Single Ended Test), where those results stop being valid, and how to keep the references behind every result trustworthy. It builds on Softing WireXpert MP Cable Tester and Dual-Ended Testing training.

What You'll Learn:

  • Tell apart fiber loopback, copper single-ended testing, and certification
  • Set up and reference fiber single-ended loopback
  • Interpret a loopback result against a loop budget
  • Use the copper Single Ended Test appropriately
  • Keep references and test cords trustworthy, and keep records

Course Structure

  1. What “Loopback” Means on the WireXpert MP
  2. Fiber Single-Ended Loopback: Setup & Reference
  3. Running a Fiber Loopback Test
  4. Copper Single-Ended Test
  5. Keeping References Trustworthy
  6. Troubleshooting & Records
  7. Final Assessment — 10 questions, 80% (8 of 10) to pass

Each section ends with a knowledge check. You get two attempts, and a first miss gives you a hint, not the answer. Finish the check to unlock the next section. You'll enter your name and email just before you submit the final assessment. Your results are emailed automatically to the training administrator, with a copy to you, whether you pass or not.

Section 1: What “Loopback” Means on the WireXpert MP

“Loopback” means testing with only the LOCAL unit: the signal leaves the tester and comes back to the same tester instead of being received by a REMOTE unit. On the WireXpert MP, this shows up in two places, and it's important to know what each one can and can't do.

FunctionWhat it isCertification?
Fiber single-ended loopbackA fiber test mode. You set the reference and run the AUTOTEST with only the LOCAL unit; light leaves its TX port and returns to its RX port.Tier 1 loss of the loop, when the project allows loopback testing
Copper Single Ended TestUses only the LOCAL unit, sometimes with a termination plug at the far end. It needs Custom limits and is disabled by default.No. It's a troubleshooting aid.
Copper certificationAlways dual-ended: LOCAL plus REMOTEYes
⚠️ There's no copper loopback certification. NEXT and return loss have to be measured from both ends of a copper link (see Dual-Ended Testing), so a single-ended copper test can never replace a dual-ended certification report.
Loopback / single-endedDual-ended
UnitsLOCAL onlyLOCAL + REMOTE
PeopleOne technicianOne or two technicians
Best forFiber loops, cord checks, quick troubleshootingCopper certification; per-fiber certification
LimitationCan't tell which part of the loop has the lossNeeds both units at opposite ends
Knowledge Check 1
Can a WireXpert MP certify a copper link using loopback or single-ended testing?
Attempts: 0/2

Section 2: Fiber Single-Ended Loopback: Setup & Reference

Know the ports

On the MP FQ (quad) fiber module, facing the touchscreen, the ports run left to right: TX singlemode, RX (shared by both fiber types), and TX multimode. The FM (multimode) and FS (singlemode) modules have one TX port each.

Setup

  1. Inspect, clean, and re-inspect every test reference cord (TRC) end-face before connecting it.
  2. Under Test Settings, choose Single-ended loopback as the test mode, then set the fiber type, limit, and reference method.
  3. For the reference, connect a test reference cord from the LOCAL unit's TX port back to its own RX port, so the light loops back into the same unit.
  4. Run Tools › Set Reference and check that the reference reading falls inside the acceptance range for your fiber type.
Fiber typeMP set-reference acceptance range (quick reference guide)
Singlemode−5.35 to +4 dBm
Multimode−25.35 to −15 dBm
TRC Verification: With TRC Verification turned on, the tester has you repeat the check through a coupler with a second set of test reference cords. This proves the cords themselves are good before any result depends on them.
⚠️ Don't unplug at the tester. After referencing, never disconnect a cord from the tester's TX or RX port. If one comes out, the reference is invalid and must be redone. Make and break connections only at the far ends of the cords.
Knowledge Check 2
How is the fiber reference made in single-ended loopback mode?
Attempts: 0/2

Section 3: Running a Fiber Loopback Test

How the loop is built

  1. Disconnect the TX and RX cords from each other only at their free ends, never at the tester.
  2. Connect the TX cord to fiber 1 at the near-end panel, and the RX cord to fiber 2 at the same panel.
  3. At the far end, join fiber 1 to fiber 2 with a short, clean loopback jumper.
  4. Press AUTOTEST. The light travels out on fiber 1, crosses the loopback jumper, and returns on fiber 2.

What the result means

The reading is the combined loss of both fibers plus the far-end loopback connections. Compare it with a loop budget that adds up both fibers' budgets plus the loopback jumper's connections. Don't compare it with a single-fiber budget.

Good usesLimitations
Testing a duplex link when you're working aloneIf the loop fails, you can't tell which fiber (or the jumper) is responsible
Checking patch cords and test cordsA low-loss fiber can hide a marginal one in the total
Quick go/no-go checks during troubleshootingMany project specifications and warranty programs require per-fiber, dual-ended results
Five 9s rule: Use loopback results for certification only when the project specification explicitly allows them. If a loop fails or looks marginal, switch to dual-ended testing to isolate the bad fiber.
Knowledge Check 3
A fiber loopback AUTOTEST reads 3.9 dB. What does that number represent?
Attempts: 0/2

Section 4: Copper Single-Ended Test

The copper Single Ended Test runs from the LOCAL unit alone. Depending on the measurement, it may need a termination plug at the far end. It's disabled by default and requires Custom limits, which is a reminder that it isn't a standards-based certification.

When it helps

  • A REMOTE unit isn't available, and you need a quick look at a suspect run
  • Finding a gross fault, such as a cut, an open, or a short, before you bring the REMOTE unit back
  • Checking a cable on the reel or a run in progress, before it's terminated for certification

When it doesn't

  • Customer acceptance or warranty reports: these need a dual-ended AUTOTEST against TIA or ISO limits
  • Any decision based on NEXT or return loss at the far end, which a single-ended test can't see
⚠️ Same safety rule as always. Single-ended or not, never connect the tester to a voltage source. Disconnect the link from active equipment first.
Knowledge Check 4
What's true about the MP's copper Single Ended Test?
Attempts: 0/2

Section 5: Keeping References Trustworthy

Every loss figure is measured against a reference. A bad reference quietly corrupts every result that follows, so this section is about keeping references trustworthy.

Copper: Set Reference

  • Done with a permanent link adapter on LOCAL, a channel adapter on REMOTE, the kit's reference cord, and the DCRU calibration artifact steps.
  • Repeat it after first pairing, firmware updates, adapter changes, long idle periods, or big changes in environment.

Fiber: reference and TRC Verification

  • Check that the reference reading falls within the acceptance range.
  • Use TRC Verification to prove the test reference cords with a second set through a coupler.
  • Re-reference if a cord is unplugged at the tester, the cords are changed, or the reading drifts.

Reference vs. calibration

Set Reference is a field step. It doesn't replace Softing's annual calibration, which keeps the instrument itself traceable. Keep the calibration certificate with the kit.

Five 9s practice: the golden link. Keep a known-good, labeled copper link and fiber jumper set at the shop. Test them at the start of each project and log the results. If a result moves noticeably from its history, clean, inspect, and re-reference, then retest. If it's still off, take the tester out of service and contact Softing support. This is our own quality practice, not a Softing requirement.
Knowledge Check 5
What does TRC Verification do?
Attempts: 0/2

Section 6: Troubleshooting & Records

Troubleshooting

SymptomLikely causeAction
Fiber reference outside the acceptance rangeDirty or damaged cord end-face, a bad cord, or the wrong portInspect, clean, and re-inspect; replace the cord; check you're on the right TX port; re-reference
Loop loss higher than the loop budgetA dirty connection somewhere in the loop, a bad loopback jumper, or one high-loss fiberClean and retest; swap the loopback jumper; then test each fiber dual-ended to isolate it
Results change between identical runsCords moved during the test, a contaminated connector, or a reference unplugged at the testerKeep cords still, clean the connections, and re-reference
Copper Single Ended Test won't runIt's disabled by default, or no Custom limit is selectedEnable it and select a Custom limit, and remember it isn't certification
Golden link drifting over weeksAdapter or cord wear, or contaminationReplace worn LongLife cords or adapters, clean, re-reference; then call service if it persists

Records

Log every reference check and golden-link test with the date, tester serial number, firmware version, the cords or adapters used, the result, and any action taken. Keep the records for as long as the project contract or warranty program requires. There's no single industry-wide retention period, so check the project documents.

Knowledge Check 6
Your weekly golden-link results have crept upward over a month. What should you do first?
Attempts: 0/2

Final Assessment

Answer all 10 questions. You need 80% (8 of 10) to pass. These questions are different from the section knowledge checks. Enter your name and email below the questions, then submit.

1. Why can't a single-ended copper test replace a dual-ended certification?
2. Which two fiber test modes does the WireXpert MP offer?
3. A fiber loopback test fails. What's the main limitation in diagnosing it?
4. When is the copper Single Ended Test the right tool?
5. Does Set Reference replace Softing's annual calibration?
6. You've just updated the firmware on both units. What's next before testing copper?
7. After referencing in fiber loopback mode, a cord is pulled out of the tester's RX port. What now?
8. What is the DCRU calibration artifact used for?
9. How long must loopback and reference-check records be kept?
10. A fiber reference reading falls outside the acceptance range. What's the most likely cause?